top of page
Durasub Fire Resistant Doors Blockade Barriers

SUPPLY & INSTALLATION OF DURASUB 4-LOUVRE FIRE DOORS 

DURASUB - D - EXT - 1-4L
AUSTRALIA STANDARD APPROVED
CLASS 1 AS1530 Part 4:2005 BLAST RESISTANT DIN 4102 PART 2 AND 3

 Durasub 4 Louvre Fire Resistant Doors

We supply and install a comprehensive range of high performance, bespoke, steel 2-4 hour fire and Blast Doors tested to Australian Standards 1905.1:2015 0/240/30

ABOUT OUR FIRE DOORS

120 Minute (2 Hour) Fire and 240-minute ( 4 Hour ) Insulation 30 minutes, Fire & Blast Doors

​

DURASUB 4-Louvre doors are manufactured using a composite panel of fibre-reinforced cement, mechanically bonded to punched steel sheets on both outer surfaces.

​

Classed as a Non-Combustible 4 hr Fire resistant Class 1 to AS1530 part 4 : 2005 Blast resistant DIN 4102 Part 2 and 3 requirements. Each door leaf fitted with two intumescent door louvres to allow for maximum air flow.

​

Approved in the Power and Energy sector, this Substation door offers durable, long-life protection for equipment and facilities.

APPLICATION AND DESIGN

Our range of hinged fire doors is to AS certified 1905.1 :2015 and BS 476 :

Part 22 1987 for up to 240 minutes integrity and 30 minutes insulation and AS1530.4-2005.

 

Blockade Barrier Fire Doors are suitable for application in Airports, Power Stations, Rail & Metro, Oil Rig and Offshore Platforms, Petrochemical, Warehouses.

 

Our range covers single and double leaf constructions for internal and external uses.

 

Our unique design of the Blockade Barrier products enables great flexibility in the manufacture, allowing almost any shape or size to be produced offering bespoke Fire Doors.

Durasub Fire Resistant Doors Blockade Barriers
Fire Doors Application and Design Blockade Barriers Melbourne Australia
TECHNICAL SPECIFICATION Fire Doors
TECHNICAL SPECIFICATIONS
Durasub Fire Resistant Doors Blockade Barriers

SUBSTATION DOOR DURASUB

D-EXT-01-4L

FEATURES
  • Fire resistance level - /240/30

  • Tested AS1530.4 -2005

  • Tested AS1905.1:2015

  • Impact resistant 2793 J

  • Corrosion resistant

  • Moisture resistant

  • Insulated Panels 

  • Intumescent door louvres 450mm x 450mm

  • 50mm thick door panels

  • Unequal angle door frame

  • Pressed metal door frame

  • Pre-hung with Hardware

  • Painted or Powder-Coated

SUBSTATION DOOR DURASUB

D-EXT-01-4L

HARDWARE
  • Piano hinges 3mm

  • Extended hinges to allow for cladding

  • TS83 Door closers

  • Panic exit device

  • 2-way extension rods

  • Night latch & handles

  • Sequence selector

CLEARING OPENING
  • Min – 1580mm x 2000mm

  • Max – 2500mm x 2500mm

STRUCTURAL WALL THICKNESS
  • Any Thickness

Durasub Fire Resistant Doors Blockade Barriers
Hardware
TECHNICAL DRAWING FIRE DOORS BLOCKADE BARRIERS MELBOURNE AUSTRALIA
TECHNICAL DRAWING
 Durasub 4 Louvre Fire Resistant Doors

DURASUB

D - EXT - 1 

​

AUSTRALIAN 

STANDARDS

AS 1905:2015

Contact Durasteel Fire & Blast Doors Australia