SUPPLY & INSTALLATION OF DURASUB SINGLE SUBSTATION FIRE DOORS 

DURASUB - S - EXT - 01
AUSTRALIA STANDARD APPROVED
CLASS 1 AS1530 Part 4:2005 BLAST RESISTANT DIN 4102 PART 2 AND 3

Blockade Barrriers Melbourne Australia F

We supply and install a comprehensive range of high performance, bespoke, steel 2-4 hour fire and Blast Doors tested to Australian Standards 1905.1:2015 0/240/30

ABOUT OUR SINGLE FIRE DOORS

120 Minute (2 Hour) Fire and 240-minute ( 4 Hour ) Insulation 30 minutes, Fire & Blast Doors

​

Durasub Single fire doors are manufactured using a composite panel of fibre-reinforced cement mechanically bonded to punched steel sheets on both outer surfaces.

​

Classed as a Non-Combustible 4 hr Fire resistant Class 1 to AS1530 part 4: 2005 Blast resistant DIN 4102 Part 2 and 3 requirements.

​

Approved in the Power and Energy sector, the Substation door offers durable long-life protection for equipment and facilities.

APPLICATION AND DESIGN

Our range of hinged fire doors is to AS certified 1905.1 :2015 and BS 476 :

Part 22 1987 for up to 240 minutes integrity and 30 minutes insulation and AS1530.4-2005.

 

Blockade Barrier Fire Doors are suitable for application in Airports, Power Stations, Rail & Metro, Oil Rig and Offshore Platforms, Petrochemical, Warehouses.

 

Our range covers single and double leaf constructions for internal and external uses.

 

Our unique design of the Blockade Barrier products enables great flexibility in the manufacture, allowing almost any shape or size to be produced offering bespoke Fire Doors.

Durasub single fire resistant doors blockade barriers
Fire Doors Application and Design Blockade Barriers Melbourne Australia
TECHNICAL SPECIFICATION Fire Doors
TECHNICAL SPECIFICATIONS
Durasub single fire resistant doors blockade barriers

SUBSTATION DOOR DURASUB

S-EXT-01

FEATURES
  • Fire resistance level - /240/30

  • Tested AS1530.4 -2005

  • Tested AS1905.1:2015

  • Impact resistant 2793 J

  • Corrosion resistant

  • Acoustic rated 49RW

  • Moisture resistant

  • Insulated Panels 

  • 50mm thick door panels

  • Unequal angle door frame

  • Pressed metal door frame

  • Pre-hung with Hardware

  • Painted or Powder-Coated

SUBSTATION DOOR DURASUB

S-EXT-01

HARDWARE
  • Piano hinges 3mm

  • Extended hinges to allow for cladding

  • TS83 Door closers

  • Panic exit device

  • 2-way extension rods

  • Night latch & handles

CLEARING OPENING
  • Min – 920mm x 2000mm

  • Max – 1500mm x 2500mm

STRUCTURAL WALL THICKNESS
  • Any Thickness

Durasub single fire resistant doors blockade barriers
Hardware
TECHNICAL DRAWING FIRE DOORS BLOCKADE BARRIERS MELBOURNE AUSTRALIA
TECHNICAL DRAWING
Substation Door Durasub-s-Ext-01

DURASUB

D - EXT - 1 

​

AUSTRALIAN 

STANDARDS

AS 1905:2015